Cylinder type sensing head size | dia. 5.4 |
---|---|
Type | Shielded |
Sensing method | Inductive type |
Sensing distance | 1 mm |
Sensing object | Ferrous metal (Sensitivity lowers with non-ferrous metals.) |
Standard sensing object | Iron 5*5*1mm |
Response frequency | 1 kHz (average) |
Standard or Different frequency | Standard |
Ambient temperature |
Operating: -25 to 70 CEL Storage: -25 to 70 CEL (with no icing or condensation) |
Ambient humidity |
Operating: 35 to 95 %RH Storage: 35 to 95 %RH (with no condensation) |
Temperature influence |
+-15% Max. of sensing distance in temperature range of -25 to +70CEL (As the basis for sensing distance of 23CEL) |
Vibration resistance | 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
Shock resistance | 500m/s2 for 3 times each in X, Y, and Z directions |
Degree of protection |
IEC60529: IP67 Company standard: Oil-proof |
Connection method | Pre-wired models (Cable length: 3 m) |
Weight (Packed state) | approx. 45 g |
Material (case) | Brass |
Material (sensing surface) | ABS |
Amplifier unit/sensor head of combination |
E2C-G*4A/JC4A(P)/A*4A |