Rated supply voltage | 100 to 240 VAC 50/60 Hz |
---|---|
Operating voltage range | 85% to 110% of rated supply voltage |
Power consumption |
Approx. 6.2 VA Note: Inrush current will flow for a short time when the power supply is turned ON. Inrush Current (Reference Values) 5.3 A (peak value) (Applied voltage: 264 VAC, Time: 0.4 ms) |
Time ranges (Number of ranges) | 10 |
Time ranges | 0.001 s to 9.999 s, 0.01 s to 99.99 s, 0.1 s to 999.9 s, 1 s to 9999 s, 0.1 min to 999.9 min, 1 min to 9999 min, 0.1 h to 999.9 h, 1 h to 9999 h, 1s to 99min59s, 1min to 99h59min |
Select method | Dip switch or Operation Key |
Input signals | Signal, Gate, Reset |
Input method | No-voltage/Voltage input (Switchable) |
No-voltage input (Solid state input) |
ON impedance: 1 kOhm max. Leakage current: Approx. 12 mA ON residual voltage: 3 V max. OFF impedance: 100 kOhm min. (The DC voltage must be 30 VDC max.) |
No-voltage input (Contact input) |
Use contact which can adequately switch 5 mA at 10 V (The DC voltage must be 30 VDC max.) |
No-voltage input (Applicable two-wire sensor) |
Leakage current: 1.5 mA max. Switching capacity: 5 mA min. Residual voltage: 3.0 VDC max. Operating voltage: 10 VDC |
Voltage input |
High: 4.5 to 30 VDC Low: 0 to 2 VDC Input resistance: 4.7 kOhm (The DC voltage must be 30 VDC max.) |
Minimum input signal width | 1 ms/ 20 ms (Switchable) (Signal, Reset, Gate) |
Standby time | 250 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.) |
Output modes | A (Signal ON delay 1), A-1 (Signal ON delay 2), A-2 (Power ON delay 1), A-3 (Power ON delay 2), b (Repeat cycle 1), b-1 (Repeat cycle 2), d (Signal OFF delay), E (Interval), F (Cumulative), Z (ON/OFF-duty adjustable flicker), S (Stopwatch), toff (Flicker OFF start 1), ton (Flicker ON start 1), toff-1 (Flicker OFF start 2), ton-1 (Flicker ON start 2) |
Control output (Contact output) |
Type: SPDT Switching capacities (Resistive load): 5 A at 250 VAC/30 VDC Minimum applicable load: 10 mA at 5 VDC (failure level: P) |
One-shot output time | 0.01 to 99.99 s |
Reset system | Power reset(A,A-1,A-2,b,d,E,Z,S,ton,toff mode), Automatic reset(A-1,b,b-1,d,E,Z,ton,toff,S,ton-1,toff-1 mode), External reset, Manual reset |
Power reset | Minimum power-opening time: 0.5 s (except for A-3, b-1, F, ton-1 and toff-1 mode) |
Timer mode | Elapsed time (UP) and remaining time (DOWN) (selectable) |
Display method | 7-segment negative transmissive LCD |
Digit | 4 digits |
Character height |
Present value: 12 mm (Red, green or orange programmable) Zero suppression: Equipped Set value: 6 mm (Green) |
Key protect Method | Key protect Switch |
Memory backup Methods | EEP-ROM (Number of rewite: 100000 times min., Service life: 10 years min.) |
Ambient temperature |
Operating: -10 to 55 CEL When mount timer side by side: -10 to 50 CEL (with no icing or condensation) Storage: -25 to 70 CEL (with no icing or condensation) |
Ambient humidity |
Operating: 25 to 85% RH Storage: 25 to 85% RH |
Total accuracy |
Accuracy of operating time and setting error (including temperature and voltage influences) Power-ON start: +/- 0.01% +/- 50 ms max. Signal start: +/- 0.005% +/- 30 ms max. The values are based on the set value. |
---|---|
Insulation resistance |
100 MOhm min. (at 500 VDC) between current carrying metal parts and exposed non-current carrying metal parts, between non-continuous contacts |
Dielectric strength |
between current-carrying metal parts and non-curernt-carrying metal parts: 2000 VAC 50/60 Hz for 1 min between input and control output and operation power circuit: 2000 VAC 50/60 Hz for 1 min between non-continuous contacts: 1000 VAC 50/60 Hz for 1 min |
Impulse withstand voltage |
between power terminals: 3 kV between current-carrying terminals and exposed non-curernt-carrying metal parts: 4.5 kV |
Noise immunity |
Between power terminals: +/- 1.5 kV Between input terminals: +/- 600 V Square-wave noise by noise simulator (Pulse width: 100 ns/1 us, Rise: 1-ns) |
Static immunity | Mulfunction: 8 kV ,Destruction: 15 kV |
Vibration resistance (Destruction) | 10 to 55 Hz, 0.75 mm single amplitude in each 3 directions for 2 hours |
Vibration resistance (Malfunction) | 10 to 55 Hz 0.35 mm single amplitude in each 3 directions for 10 min |
Shock resistance (Destruction) | 300 m/s**2, in each 6 directions (3 axes) 3 times |
Shock resistance (Malfunction) | 100 m/s**2, in each 6 directions (3 axes) 3 times |
Mechanical Life expectancy (relay output) | 10000000 operations min. (under no load at 1800 operations/h) |
Electrical Life expectancy (relay output) | 100000 operations min. (5 A at 250 VAC resistive load at 1800 operations/h) |
Degree of protection | IEC60529(JEM): Panel surface: IEC IP66, UL508 Type 4X (indoors) (when using the Y92S-29 Waterproof Packing and Y92F-30 Flush Mounting Adapter), Case rear: IP40, Terminal block: IP20 |
Applicable standard (UL) |
Standard No.: UL508 File number: E41515 |
Applicable standard (CSA) |
Standard No.: CSA C22.2 No.14 File number: LR22310 |
Applicable standard (VDE) | VDE0106/P100 |
Applicable standard (EC Directive (Machinery Directive) ) | EN61812-1 |
Applicable standard (EC Directive (Low Voltage Directive) ) | EN61812-1 |
Applicable standard (EC Directive (EMC Directive) ) |
EMI: EN61812-1 Emission Enclosure: EN55011 Group 1 class A Emission AC mains: EN55011 Group 1 class A EMS: EN61812-1 Immunity ESD: EN61000-4-2 (6 kV contact discharge (level 2), 8 kV air discharge (level 3)) RF-interference: EN61000-4-3 (10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) (level 3), 10 V/m (Pulse-modulated, 900 MHz 5 MHz) (level 3)) Immunity Conducted Disturbance: EN61000-4-6 (10 V (0.15 to 80 MHz) (level 3)) Immunity Burst: EN61000-4-4 (2 kV power-line (level 3), 1 kV I/O signal-line (level 4)) Immunity Surge: EN61000-4-5 (1 kV line to lines (power and output lines) (level 3), 2 kV line to ground (power and output lines) (level 3)) |
Applicable standard (Others) | Immunity Voltage Dip/Interruption: EN61000-4-11 (0.5 cycle, 100% (rated voltage)) |
Mounting method | Flush mounting |
external connection method | Screw terminals |
Case color | Black (Munsell N1.5) (The front part can be changed to light gray or white in sold separately panel) |
Attachment |
Flush mounting adapter Waterproof rubber packing Label for DIP switch settings Shock Prevention Cover |
Accessory (sold separately) |
Soft Cover (Y92A-48F1) Hard Cover (Y92A-48) Flush Mounting Adapter (Y92F-30) Flush Mounting Adapter (Y92F-45) Waterproof Packing (Y92S-29) Replacement Front Panel (Y92P-CXT4S) Replacement Front Panel (Y92P-CXT4G) Replacement Front Panel (Y92P-CXT4B) |
Weight | Approx. 115 g |